Chapter 04
Wiring and signal path
Pick a compartment and run an unlock to follow the command from the app to the lock. You can also simulate a mains or internet outage.
Data
Power 12 V / 5 V
Active path
Bus termination
Choose a compartment, then run the unlock.
Connection list
| From | To | Cable |
|---|---|---|
| Mains 230 V | IEC inlet (switch + fuse) → PSU 12 V 5 A | 3-core mains cable |
| PSU 12 V output | DC UPS module → battery and load output | 1 mm², red/black |
| UPS load output | 5 A fuse → board 1 power input | 1 mm², red/black |
| Board 1 → 2 → 3 | Cascade ports P1 / P2 | Supplied 4-wire cable |
| Raspberry Pi USB | USB-RS485 converter | Direct plug |
| Converter A, B, GND | Board 1 A, B, GND | Twisted pair (e.g. Cat5e pair) |
| UPS load output | Buck 12→5 V → Raspberry Pi USB-C | 5 V 3 A |
| Each board channel | Its lock (coil + door sensor) | Supplied harness, via ducts |
Five rules for a first-time-right install
- Give each board a unique address (01, 02, 03) with its DIP switches or buttons.
- Don't swap A and B. If nothing answers, check this first.
- Tie every ground (GND) together: PSU, boards and converter.
- Fit a 120 Ω termination on the last board of the chain. It's often on-board, enabled by a jumper.
- Fuse the 12 V output at 5 A.
Only one lock fires at a time. A pulse draws about 1 A for 0.5 s, so a 5 A supply leaves good margin. Never trigger several locks at once from the software.