Docs

Chapter 08

Security and resilience

Security is layered: the backend decides who may open what, every command is signed and short-lived, traffic is encrypted end to end, and the cabinet keeps working through power and network outages.

Access control

  • The app never addresses a lock directly. The backend checks ownership on every request.
  • Commands are signed (HMAC or Ed25519), single-use and expire within 30 s.
  • Optional presence check: the customer scans a QR code on the cabinet or is within BLE range.

Transport

  • TLS everywhere: HTTPS for the app, MQTT on port 8883 for the cabinet.
  • One client certificate per cabinet, revocable from the backend.
  • The broker's ACLs restrict each cabinet to its own topics.

Power and network outages

  • The DC UPS and battery keep the cabinet running for about 15 h (7 Ah at about 4 W idle).
  • Offline mode: BLE with a pre-issued, signed and time-limited token stored in the app. Events sync when the cabinet reconnects.
  • Fail-secure locks stay locked without power.

Physical

  • 1.5 mm steel, with the hatch and rear panel under key or tamper-proof screws.
  • Mechanical override for the service team, logged on use.
  • Anchor the cabinet to the wall and floor.

Audit

  • Every request, unlock and door event is logged with the user, time and result.
  • Alert when a door is left open too long, or opens without a command.

Device hardening

  • Read-only root filesystem or overlay. SSH by key only, or disabled.
  • Automatic security updates and a hardware watchdog.
  • Secrets stored outside the code with restricted file permissions.